 leak detection tubes
   Leak Detection Tubes     
Double-walled leak detection tubes are most commonly used in power generation and electric motor cooling in order to protect a motor or control panel in the event of a heat exchanger leak.

A leak detection tube, which is made from two individual tubes with longitudinal flutes, channels leaked water to a collection point to ensure that any leaked water is kept away from vulnerable components and is easily identified. Identifying the problem before a major process fault develops allows time to test and isolate the leak either with the use of the patented jiffy-plug system or arrange for a re-tube to be carried out.
Applied Cooling Technology is the only non-OEM heat exchanger manufacturer in the world who holds significant stocks of leak detection tubes for a fast response to client requirements. Tubes are finned using the ElfinMaster method of swaging fins on to the tube - ideal for double-walled tubes.Other product categories:-
Heat Exchangers
Finned Tubes and Cores

Other products:-
Condenser Ferrules
Condenser Packing Ring Seals Fibre and Metallic
Heat Exchanger and Condenser Tubes
Tube Inserts
Non-Destructive Tube Plugs
Facade Tubeplate Protection
U-Tubes and Coils
Call us now in the UK on +44 (0)121 748 8400 or in the USA on +1 239 217 5080 or e-mail the Sales Team